Difference between revisions of "Template:S1 Pro Battery"

From Bose Portable PA Encyclopedia
Jump to: navigation, search
m
m
Line 1: Line 1:
 +
=== Documentation ==
 +
[[Media:S1 Pro Battery Owners Guide.pdf|S1 Pro Battery Owners Guide]]
 
=== Run Time ===
 
=== Run Time ===
  

Revision as of 16:27, 4 October 2019

= Documentation

S1 Pro Battery Owners Guide

Run Time

Up to 11 hours of play .

The full output of the S1 Pro system is available even when running on the internal battery. This is unlike some systems that throttle performance to extend the battery life.

Your run time will vary based on:

  • Volume and to a lesser extent the tone controls
Higher volume and turning up the tone controls draws more energy than lower settings.
  • Program material
Prerecorded music is usually compressed. This may draw more power than live music at the same perceived volume because live music has more dynamics (lower draw in quiet moments).

Charging Times

Estimates:

  • 6.0 hours Trickle charge (system idle, connected to AC Power), switch in Off or Play position
  • 2.5 hours Fast charge (connected to AC Power), switch in Fast Charge (down) position


Checking the Battery Level

To check the battery, turn on the S1 Pro (switch in the top position). Wait until the power light is steady blue. Double tap the Bluetooth button (tap tap in under a second). Count how many times the power light blinks before returning to steady blue.

NOTE If you are running your S1 Pro System and battery LED turns solid red - the battery is nearly out of power. Connect to AC power to keep the show going.

S1 Pro Battery Charging.jpg


Battery Specifications

S1 Pro Battery Label

Battery Life

Bose does not make claims about battery life however, you may find this article useful Battery Life.

Temperature Considerations

Please note the following information from the S1 Pro Battery Pack Owner’s Guide:

  • Charging temperature range: 0°C - 42°C (32°F - 108°F)
  • Discharging temperature range: -20°C - 45°C (-4°F - 113°F)

You can operate the S1 Pro on the battery pack down to -20°C (-4°F), The running time may be reduced but not significantly.

NOTE
The battery does not charge temperatures below 0°C (32°F).


The battery will stop charging when the temperature is below 0°C - 42°C (32°F - 108°F) but the charging light may continue to flash.

The battery will stop functioning below -20°C - 45°C (-4°F - 113°F)


If you have questions on this point please see Battery Life in the Cold

Installation

S1 Pro Battery Installation.jpg


The screw heads are Phillips.

S1 Pro Phillips.jpg Philips head screwdriver Horz.jpg

Note: The screws remain attached to the battery cover. You can't misplace or lose them because they don't separate from the battery cover.


Flying with the Lithium Ion Battery

Here's some information about Flying with Lithium Ion batteries from the FAA

https://www.faa.gov/about/init.../more_info/?hazmat=7

Size limits: Lithium metal (non-rechargeable) batteries are limited to 2 grams of lithium per battery. Lithium ion (rechargeable) batteries are limited to a rating of 100 watt hours (Wh) per battery. These limits allow for nearly all types of lithium batteries used by the average person in their electronic devices. With airline approval, passengers may also carry up to two spare larger lithium ion batteries (101-160 watt hours). This size covers the larger after-market extended-life laptop computer batteries and some larger batteries used in professional audio/visual equipment.

The battery in the S1 Pro is rated at 79.20 Wh. That's not in the documentation, but it is on the label on the battery.